PRODUCTSAUXILIARY CIRCUIT COMPONENTS
Cushion Valve
Model No. CUV-404 (Electrically Actuated)
- High-speed operation and abrupt stop of the cylinder are possible.
- Soft stop is possible through back pressure adjustment.
- Prevents the wear of equipment due to shock and extends lifetime.
- Improves the operation rate of the device.
- Applicable cylinder diameter: Ø80 max.
Standard specifications
| Operating fluid | Compressed air filtered by a filter | ||
| Maximum allowable pressure | 1.0 MPa | ||
| Applicable cylinder diameter | Ø80 max. | ||
| Cylinder loading rate | 40% max. (including weight of piston and rod) | ||
| Operating pressure range | 0.3-0.6 MPa | ||
| Operating temperature | 5-50°C | ||
| Lubrication | Lubrication required (turbine oil ISO VG32 or equivalent) | ||
| Rated voltage | ・AC 100 V 50/60 Hz, AC 110 V 60 Hz ・AC 200 V 50/60 Hz, AC 220 V 60 Hz ・DC 24 V |
||
| Allowable voltage fluctuation rate | −15% to +10% | ||
| Insulation type | Type B |
Current value of the solenoid
| - | Voltage/frequency | 50 Hz | 60 Hz |
| Holding current | AC 100 V | 0.102 A | 0.079 A |
| AC 200 V | 0.049 A | 0.039 A | |
| Direct current | DC 24 V | 0.270 A | |
Typical characteristic values
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
Weight (kg) | ||
| Direction control valve Connection port (V) |
Cylinder Connection port (C) |
Back pressure adjustment air Connection port (P) |
|||
| CUV-404 | Rc1/2 | Rc1/4 | 100 <5.4> | 1 | |
Model No.
| CUV-404 | S | P | AC 100 fV |
| Product name | [1] | [2] | [3] |
[1]Electrical connection
| Blank | DIN terminal |
| S | With DIN terminal and indicator lamp |
[2]Pilot air supply method
| Blank | Internal pilot air supply method |
| P | External pilot air supply method |
[3]Rated voltage
| AC100V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Model No. CUV-404A (Air Pilot Actuated)
- High-speed operation and abrupt stop of the cylinder are possible.
- Soft stop is possible through back pressure adjustment.
- Prevents the wear of equipment due to shock and extends lifetime.
- Improves the operation rate of the device.
- Applicable cylinder diameter: Ø80 max.
Standard specifications
| Operating fluid | Compressed air filtered by a filter | ||
| Maximum allowable pressure | 1.0 MPa | ||
| Applicable cylinder diameter | Ø80 max. | ||
| Cylinder loading rate | 40% max. (including weight of piston and rod) | ||
| Operating pressure range | 0.25-0.6 MPa | ||
| Operating temperature | 5-60°C | ||
| Lubrication | Lubrication required (turbine oil ISO VG32 or equivalent) |
Typical characteristic values
| Model No. | Pipe connection threads | Effective cross-sectional area (mm²) < Cv value > |
Weight (kg) | |||
| Direction control valve Connection port (V) |
Cylinder Connection port (C) |
Back pressure adjustment air Connection port (P) |
Signal port | |||
| CUV-404A | Rc1/2 | Rc1/4 | 100 <5.4> | 0.75 | ||