PRODUCTSDIRECTION CONTROL VALVES (EXCEPT FOR DUAL VALVE)
Direct-Acting Solenoid Valve (3/5-Port)
Direct-Acting Solenoid Valve (3-Port) Model No. MVS-303
- Direct-acting air pressure three-way valve that directly applies the force of a magnet (electromagnetic force) to the valve to switch the air passage
- Operating only with an electromagnetic force, the valve can also be used in a low pressure circuit close to 0 MPa.
- In-line direct-acting solenoid valve
- Can be used without an oil supply.
- High response speed and stability
Standard specifications
| Valve function | Direct-acting solenoid valve (3-Port), single solenoid normally closed | |||||
| Operating fluid | Compressed air filtered by a filter | |||||
| Operating pressure range | 0-1.0 MPa | |||||
| Lubrication | ISO VG32 turbine oil* | |||||
| Ambient temperature | 5-50°C | |||||
| Manual operations | Non-locking type manual push button | |||||
| Restriction on the installation direction | None | |||||
| Rated voltage | ・AC 100 V 50 Hz, AC 110 V 60 Hz ・AC 200 V 50 Hz, AC 220 V 60 Hz ・DC 24 V |
|||||
| Allowable voltage fluctuation rate | −15% to +10% of the rated voltage | |||||
| Insulation type | Type B | |||||
* Can be used even without an oil supply.
Current value of the solenoid
| - | Voltage/frequency | 50 Hz | 60 Hz |
| Striking current | AC 100 V | 0.510 A | 0.435 A |
| AC 200 V | 0.260 A | 0.220 A | |
| Holding current | AC 100 V | 0.240 A | 0.192 A |
| AC 200 V | 0.120 A | 0.096 A | |
| Direct current | DC 24 V | 0.54 A | |
Typical characteristic values
| Model No. | Pipe connection threads | Response time* (msec) | Weight (kg) | Effective cross-sectional area (mm²) < Cv value > | ||
| ON | OFF | IN - OUT | OUT - EX | |||
| MVS-303-02Y | Rc1/4 | 6 | 8 | 0.7 | 7 <0.38> | 7.5 <0.40> |
* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.
Model No.
| MVS-303 | - | 02Y | H | R | DC24V |
| Product name | [1] | [2] | [3] |
[1]Voltage type
| Blank | AC |
| H | DC |
[2]Accessories
| Blank | Non-locking type manual push button |
| R | Locking type manual push button |
| S | Indicator lamp and surge killer |
[3]Rated voltage
| AC 100 V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.
Direct-Acting Solenoid Valve (3-Port) Model No. 392-_00
- In-line connection model (Rc1/4, Rc3/8)
- Universal port for which the valve function can be selected according to use
- The models for compressed air and vacuum are available.
- The installation bracket is included.
- Operating pressure: 0-0.7 MPa (for compressed air), 0.1-0 MPa (for vacuum)
- Rated voltage: AC 100/200 V (50/60 Hz), DC 24 V
Standard specifications
| Operating fluid | Compressed air filtered by a filter | |||
| Operating pressure range | For compressed air | 0-0.7 MPa | ||
| For vacuum | −0.1-0 MPa | |||
| Ambient temperature | 5-50°C | |||
| Lubrication | Not required | |||
| Manual operations | Non-locking type push button | |||
| Restriction on the installation direction | None | |||
| Ratings of the solenoid | Rated voltage | ・AC 100 V 50/60 Hz, AC 110 V 60 Hz ・AC 200 V 50/60 Hz, AC 220 V 60 Hz ・DC 24 V |
||
| Allowable voltage fluctuation rate | −15% to +10% of the rated voltage | |||
| Insulation type | Type B | |||
Current value of the solenoid
| - | Voltage/frequency | 50 Hz | 60 Hz |
| Striking current | AC 100 V | 0.205 A | 0.176 A |
| AC 200 V | 0.103 A | 0.088 A | |
| Holding current | AC 100 V | 0.180 A | 0.146 A |
| AC 200 V | 0.088 A | 0.072 A | |
| Direct current | DC 24 V | 0.430 A | |
Typical characteristic values
| Model No. | Pipe connec-tion threads | Effective cross-sectional area (mm²) |
Response time* (msec) |
Weight (kg) |
||||
| For compressed air (0-0.7 MPa) | For vacuum (−0.1-0 MPa) | |||||||
| Standard model | Indicator lamp With surge killer |
Standard model | Indicator lamp With surge killer |
ON | OFF | |||
| 392-200-60B1 | 392-200-60B4 | 392-200-02B1 | 392-200-02B4 | Rc1/4 | 11 | 7 | 6.5 | 0.5 |
| 392-300-60B1 | 392-300-60B4 | 392-300-02B1 | 392-300-02B4 | Rc3/8 | ||||
* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.
Model No.
| 392 | - | 2 | 00 | - | 60 | B | 1 | AC100V |
| Product name | [1] | [2] | [3] | [4] | [5] |
[1]Pipe connection threads
| 2 | Rc1/4 |
| 3 | Rc3/8 |
[2]Function
| 60 | Compressed air, universal port model |
| 02 | Vacuum, normally closed model |
[3]Inclusion of the bracket
| B | With bracket |
| 0 | Without bracket |
[4]Electrical connection
| 1 | DIN connector |
| 4 | With DIN connector and indicator lamp |
[5]Rated voltage
| AC 100 V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.
Direct-Acting Solenoid Valve (5-Port) Model No. MVS/D-490_
- The direct-acting spool valve has good responsiveness and can operate frequently.
- The newly developed solenoid further improves durability.
- No air loss
Standard specifications
| Operating fluid | Compressed air filtered by a filter | |||
| Operating pressure range | 0-1.0 MPa | |||
| Ambient temperature | 5-50°C | |||
| Lubrication | ISO VG32 turbine oil | |||
| Manual operations | Non-locking type push button | |||
| Restriction on the installation direction | None | |||
| Ratings of the solenoid | Rated voltage | ・AC 100 V 50/60 Hz, AC 110 V 60 Hz ・AC 200 V 50/60 Hz, AC 220 V 60 Hz ・DC 24 V |
||
| Allowable voltage fluctuation rate | −15% to +10% of the rated voltage | |||
| Insulation type | Type B | |||
Current value of the solenoid
| - | Voltage/frequency | 50 Hz | 60 Hz |
| Striking current | AC 100 V | 0.750 A | 0.630 A |
| AC 200 V | 0.380 A | 0.335 A | |
| Holding current | AC 100 V | 0.240 A | 0.192 A |
| AC 200 V | 0.120 A | 0.096 A | |
| Direct current | DC 24 V | 0.540 A | |
Typical characteristic values
| Valve function | Pipe connection threads | Model No. | Effective cross-sectional area (mm²) |
Response time (msec) |
Weight For alternate current and direct current (kg) |
|||
| Standard model (for alternate current) |
Indicator lamp With surge killer (for alternate current) |
For direct current | ON | OFF | ||||
| Single solenoid | Rc1/4 | MVS-4902 | MVS-4902S | MVS-4902H | 9 | 8 | 11 | 1.0/1.4 |
| Rc3/8 | MVS-4903 | MVS-4903S | MVS-4903H | |||||
| Single solenoid | Rc1/4 | MVD-4902 | MVD-4902S | MVD-4902H | - | 1.3/2.1 | ||
| Rc3/8 | MVD-4903 | MVD-4903S | MVD-4903H | |||||
Model No.
| MV | S | - | 49 | 02 | H | R | DC24V |
| [1] | [2] | [3] | [4] | [5] |
[1]Number of solenoids
| S | Single solenoid |
| D | Double solenoid |
[2]Pipe connection threads
| 02 | Rc1/4 |
| 03 | Rc3/8 |
[3]Voltage type
| Blank | AC |
| H | DC |
[4]Accessories
| Blank | Non-locking type manual push button |
| R | Locking type manual push button |
| S | Indicator lamp and surge killer |
[5]Rated voltage
| AC 100 V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.