PRODUCTSDIRECTION CONTROL VALVES (EXCEPT FOR DUAL VALVE)

Poppet Type Solenoid Valve (2/3/4-Port)

Poppet Type Solenoid Valve (2-Port) Model No. 263/8-_01, Model No. 26B-_00

Model No. 263/8-_01, Model No. 26B-_00
  • Poppet structure that facilitates maintenance
  • The pilot method achieves reliable operation
  • Ideal as a switch valve for a large flow rate.
  • Normally closed and open valves are available.
  • The internal pilot can easily be modified to the external pilot using a rubber plug.
  • Valve with superior durability
  • Can be used without an oil supply.

Standard specifications

Operating fluid Compressed air filtered by a filter
Operating pressure range Internal pilot air supply method 0.15-1.0 MPa
External pilot air supply method 0.05-1.0 MPa
Withstand pressure 1.6 MPa
Ambient temperature 5-50°C
Lubrication Lubrication required (ISO VG32 turbine oil or equivalent)*
Standard accessories Non-locking type manual push button and installation bracket
Rated voltage ・AC 100 V 50 Hz, AC 110 V 60 Hz
・AC 200 V 50 Hz, AC 220 V 60 Hz
・DC 24 V
Allowable voltage fluctuation rate −15% to +10% of the rated voltage
Insulation type Type B

* Can be used even without an oil supply.

Current value of the solenoid (two-position type)

Two-position type - Model No. 263/8-_01 Model No. 26B-_00
Voltage/frequency 50 Hz 60 Hz 50 Hz 60 Hz
Striking current AC 100 V 0.30 A [0.065 A] 0.26 A [0.058 A] 0.510 A [0.750 A] 0.435 A [0.630 A]
AC 200 V 0.15 A [0.035 A] 0.13 A [0.032 A] 0.260 A [0.380 A] 0.220 A [0.335 A]
Holding current AC 100 V 0.20 A [0.040 A] 0.18 A [0.033 A] 0.240 A [0.240 A] 0.192 A [0.192 A]
AC 200 V 0.10 A [0.075 A] 0.09 A [0.019 A] 0.120 A [0.120 A] 0.096 A [0.096 A]
Direct current DC 24 V 0.40 A [0.075 A] 0.646 A [0.646 A]

Notes:

  • The current values in square brackets are for the two-position double solenoid.
  • For other voltages, contact Azbil TA Co., Ltd.

Typical characteristic values

●Two-position single solenoid normally closed

Model No. Pipe connection threads (IN and OUT) Effective cross-sectional area (mm²)
< Cv value >
Response time*
(msec)
Weight (kg)
IN - OUT
263-201-00B0 Rc1/4 40 <2.2> 40 or less 1.1
263-301-00B0 Rc3/8 58 <3.1>
263-401-00B0 Rc1/2 71 <3.8>
268-401-00B0 106 <5.7> 50 or less 1.8
268-601-00B0 Rc3/4 170 <9.1>
268-801-00B0 Rc1 190 <10.2>
268-A01-00B0 Rc1 1/4 190 <10.2>
26B-A00-01B0 450 <24.3> 50 or less 6.2
26B-B00-01B0 Rc1 1/2 510 <27.5>
26B-C00-01B0 Rc2 570 <30.8>

●Two-position single solenoid normally open

Model No. Pipe connection threads (IN and OUT) Effective cross-sectional area (mm²)
< Cv value >
Response time*
(msec)
Weight (kg)
IN - OUT
263-201-10B0 Rc1/4 40 <2.2> 40 or less 1.1
263-301-10B0 Rc3/8 53 <2.9>
263-401-10B0 Rc1/2 63 <3.4>
268-401-10B0 112 <6.1> 50 or less 1.8
268-601-10B0 Rc3/4 170 <9.1>
268-801-10B0 Rc1 190 <10.2>
268-A01-10B0 Rc1 1/4 190 <10.2>
26B-A00-11B0 480 <25.9> 50 or less 6.2
26B-B00-11B0 Rc1 1/2 550 <29.7>
26B-C00-11B0 Rc2 600 <34.4>

●Two-position double solenoid

Model No. Pipe connection threads (IN and OUT) Effective cross-sectional area (mm²)
< Cv value >
Response time*
(msec)
Weight (kg)
IN - OUT
263-201-20B0 Rc1/4 40 <2.2> 40 or less 1.2
263-301-20B0 Rc3/8 58 <3.1>
263-401-20B0 Rc1/2 71 <3.8>
268-401-20B0 106 <5.7> 50 or less 1.9
268-601-20B0 Rc3/4 170 <9.1>
268-801-20B0 Rc1 190 <10.2>
268-A01-20B0 Rc1 1/4 190 <10.2>
26B-A00-21B0 450 <24.3> 60 or less 6.8
26B-B00-21B0 Rc1 1/2 510 <27.5>
26B-C00-21B0 Rc2 570 <30.8>

* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.

Notes:

  • Show the rated voltage at the end of the model No.
  • Model No. 26B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.

Model No.

26 3 - 2 01 - 0 0 B 0 AC100V
Product name [1] [2] [3] [4] [5] [6] [7]

[1]Basic body size

3 3/8B
8 1B
B 1 1/2B

[2]Pipe connection threads

2 Rc1/4
3 Rc3/8
4 Rc1/2
6 Rc3/4
8 Rc1
A Rc1 1/4
B Rc1 1/2
C Rc2

[3]Function

0 Single solenoid, normally closed
1 Single solenoid, normally open
2 Double solenoid

[4]Pilot air supply method

0 Internal pilot air supply method
1 External pilot air supply method

[5]Accessories

B Non-locking type manual push button and installation bracket
R Locking type manual push button and installation bracket

[6]Operation method

0 Solenoid
2 Solenoid with indicator lamp and surge killer

[7]Rated voltage

AC 100 V AC 100 V 50/60 Hz, AC 110 V 60 Hz
AC 200 V AC 200 V 50/60 Hz, AC 220 V 60 Hz
DC 24 V DC 24 V

Notes:

  • If a voltage other than the above is required, specify the voltage and cycle.

Poppet Type Solenoid Valve (3-Port) Model No. 363/8-_01, Model No. 36B-_00

Model No. 363/8-_01、Model No. 36B-_00
  • Poppet structure that facilitates maintenance
  • The external pilot method achieves reliable operation.
  • Ideal as a control valve for a large flow rate.
  • Valve with superior durability
  • Can be used without an oil supply.

Standard specifications

Operating fluid Compressed air purified by a filter
Operating pressure range Internal pilot air supply method 0.15-1.0 MPa*1
External pilot air supply method 0.05-1.0 MPa
Withstand pressure 1.6 MPa
Ambient temperature 5-50°C
Lubrication Lubrication required (ISO VG32 turbine oil or equivalent)*2
Standard accessories Non-locking type manual push button and installation bracket
Rated voltage ・AC 100 V 50 Hz, AC 110 V 60 Hz
・AC 200 V 50 Hz, AC 220 V 60 Hz
・DC 24 V
Allowable voltage fluctuation rate −15% to +10% of the rated voltage
Insulation type Type B

*1 The operating pressure range of Model No. 36B-_00 is 0.2 to 1.0 MPa.

*2 Can be used even without an oil supply.

Current value of the solenoid (two-position type)

- - Model No. 363/8-_01 Model No. 36B-_00
Voltage/frequency 50 Hz 60 Hz 50 Hz 60 Hz
Striking current AC 100 V 0.30 A [0.065 A] 0.26 A [0.058 A] 0.510 A [0.750 A] 0.435 A [0.630 A]
AC 200 V 0.15 A [0.035 A] 0.13 A [0.032 A] 0.260 A [0.380 A] 0.220 A [0.335 A]
Holding current AC 100 V 0.20 A [0.040 A] 0.18 A [0.033 A] 0.240 A [0.240 A] 0.192 A [0.192 A]
AC 200 V 0.10 A [0.022 A] 0.09 A [0.019 A] 0.120 A [0.120 A] 0.096 A [0.096 A]
Direct current DC 24 V 0.40 A [0.075 A] 0.646 A [0.646 A]

Notes:

  • The current values in square brackets are for the two-position double solenoid.
  • For other voltages, contact Azbil TA Co., Ltd.

Typical characteristic values

●Two-position double solenoid

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
Response time*
(msec)
EX port pipe connection threads Weight (kg)
IN - OUT OUT - EX
363-201-20B0 Rc1/4 42.5 <2.3> 56 <3.0> 40 or less Rc1/2 1.2
363-301-20B0 Rc3/8 63 <3.4> 85 <4.6>
363-401-20B0 Rc1/2 75 <4.0> 100 <5.4>
368-401-20B0 106 <5.7> 160 <8.6> 40 or less Rc1 1.9
368-601-20B0 Rc3/4 170 <9.1> 236 <12.7>
368-801-20B0 Rc1 190 <10.2> 250 <13.5>
368-A01-20B0 Rc1 1/4 190 <10.2> 250 <13.5> Rc1 1/4
36B-A00-21B0 450 <24.3> 530 <28.6> 40 or less Rc2 6.8
36B-B00-21B0 Rc1 1/2 500 <27.0> 600 <32.4>
36B-C00-21B0 Rc2 530 <28.6> 600 <32.4>

* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.

Notes:

  • Show the rated voltage at the end of the model No.
  • Model No. 36B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.

●Two-position single solenoid normally closed

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
Response time*
(msec)
EX port pipe connection threads Weight (kg)
IN - OUT OUT - EX
363-201-00B0 Rc1/4 42.5 <2.3> 56 <3.0> 30 or less Rc1/2 1.1
363-301-00B0 Rc3/8 63 <3.4> 85 <4.6>
363-401-00B0 Rc1/2 75 <4.0> 100 <5.4>
368-401-00B0 106 <5.7> 160 <8.6> 30 or less Rc1 1.8
368-601-00B0 Rc3/4 170 <9.1> 236 <12.7>
368-801-00B0 Rc1 190 <10.2> 250 <13.5>
368-A01-00B0 Rc1 1/4 190 <10.2> 250 <13.5> Rc1 1/4
36B-A00-01B0 450 <24.3> 530 <28.6> 30 or less Rc2 6.2
36B-B00-01B0 Rc1 1/2 500 <27.0> 600 <32.4>
36B-C00-01B0 Rc2 530 <28.6> 600 <32.4>

* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.

Notes:

  • Show the rated voltage at the end of the model No.
  • Model No. 36B-_00 (Rc1 1/4 to Rc2) above uses air supply with the external pilot method.

●Two-position single solenoid normally open

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
Response time*
(msec)
EX port pipe connection threads Weight (kg)
IN - OUT OUT - EX
363-201-10B0 Rc1/4 47.5 <2.5> 56 <3.0> 30 or less Rc1/2 1.1
363-301-10B0 Rc3/8 60 <3.2> 71 <3.8>
363-401-10B0 Rc1/2 63 <3.4> 71 <3.8>
368-401-10B0 112 <6.0> 140 <7.5> 30 or less Rc1 1.8
368-601-10B0 Rc3/4 150 <8.1> 176 <9.5>
368-801-10B0 Rc1 190 <10.2> 180 <9.7>
368-A01-10B0 Rc1 1/4 190 <10.2> 180 <9.7> Rc1 1/4
36B-A00-11B0 400 <21.6> 425 <22.9> 30 or less Rc2 6.2
36B-B00-11B0 Rc1 1/2 480 <25.9> 500 <27.0>
36B-C00-11B0 Rc2 480 <25.9> 500 <29.0>

* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.

Notes:

  • Show the rated voltage at the end of the model No.
  • Model No. 36B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.

Model No.

36 3 - 2 01 - 0 0 B 0 AC100V
Product name [1] [2] [3] [4] [5] [6] [7]

[1]Basic body size

3 3/8B
8 1B
B 1 1/2B

[2]Pipe connection threads

2 Rc1/4
3 Rc3/8
4 Rc1/2
6 Rc3/4
8 Rc1
A Rc1 1/4
B Rc1 1/2
C Rc2

[3]Function

0 Single solenoid, normally closed
1 Single solenoid, normally open
2 Double solenoid

[4]Pilot air supply method

0 Internal pilot air supply method
1 External pilot air supply method

[5]Accessories

B Non-locking type manual push button and installation bracket
R Locking type manual push button and installation bracket

[6]Operation method

0 Solenoid
2 Solenoid with indicator lamp and surge killer

[7]Rated voltage

AC 100 V AC 100 V 50/60 Hz, AC 110 V 60 Hz
AC 200 V AC 200 V 50/60 Hz, AC 220 V 60 Hz
DC 24 V DC 24 V

Notes:

  • If a voltage other than the above is required, specify the voltage and cycle.

Poppet Type Solenoid Valve (4-Port) Model No. 463/8-_01, Model No. 46B-_00

Model No. 463/8-_01、Model No. 46B-_00
  • High durability
  • Flange connection that facilitates installation and removal of the unit
  • DIN-type electric wire connector
  • The pipe connection direction can be switched.
  • The internal and external pilot methods can be switched.
  • Can be used without an oil supply.

Standard specifications

Operating fluid Compressed air purified by a filter
Operating pressure range Internal pilot air supply method 0.15-1.0 MPa*1
External pilot air supply method 0.05-1.0 MPa
Withstand pressure 1.6 MPa
Ambient temperature 5-50°C
Lubrication Lubrication required (ISO VG32 turbine oil or equivalent)*2
Standard accessories Non-locking type manual push button and installation bracket
Rated voltage ・AC 100 V 50 Hz, AC 110 V 60 Hz
・AC 200 V 50 Hz, AC 220 V 60 Hz
・DC 24 V
Allowable voltage fluctuation rate −15% to +10% of the rated voltage
Insulation type Type B

*1 The operating pressure range of Model No. 46B-_00 is 0.2 to 1.0 MPa.

*2 Can be used even without an oil supply.

Current value of the solenoid (two-position type)

Two-position type - Model No. 463/8-_01 Model No. 46B-_00
Voltage/frequency 50 Hz 60 Hz 50 Hz 60 Hz
Striking current AC 100 V 0.30 A [0.065 A] 0.26 A [0.058 A] 0.510 A [0.750 A] 0.435 A [0.630 A]
AC 200 V 0.15 A [0.035 A] 0.13 A [0.032 A] 0.260 A [0.380 A] 0.220 A [0.335 A]
Holding current AC 100 V 0.20 A [0.040 A] 0.18 A [0.033 A] 0.240 A [0.240 A] 0.192 A [0.192 A]
AC 200 V 0.10 A [0.075 A] 0.09 A [0.019 A] 0.120 A [0.120 A] 0.096 A [0.096 A]
Direct current DC 24 V 0.40 A [0.075 A] 0.646 A [0.646 A]

Notes:

  • The current values in square brackets are for the two-position double solenoid.
  • For other voltages, contact Azbil TA Co., Ltd.

Current value of the solenoid (three-position type)

Three-position type - Model No. 463/8-_01 Model No. 46B-_00
Voltage/frequency 50 Hz 60 Hz 50 Hz 60 Hz
Striking current AC 100 V 0.30 A [0.065 A] 0.26 A [0.058 A] 0.510 A [0.750 A] 0.435 A [0.630 A]
AC 200 V 0.15 A [0.022 A] 0.13 A [0.018 A] 0.260 A [0.380 A] 0.220 A [0.335 A]
Holding current AC 100 V 0.20 A [0.040 A] 0.18 A [0.033 A] 0.240 A [0.240 A] 0.192 A [0.192 A]
AC 200 V 0.10 A [0.022 A] 0.09 A [0.019 A] 0.120 A [0.120 A] 0.095 A [0.095 A]
Direct current DC 24 V 0.40 A [0.085 A] 0.646 A [0.646 A]

Notes:

  • The current values in square brackets are for the three-position type closed center model.
  • For other voltages, contact Azbil TA Co., Ltd.

Typical characteristic values

●Two-position single solenoid

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
Response time*
(msec)
EX port pipe connection threads Weight
(kg)
IN - OUT OUT - EX
IN → 01 IN → 02 01 → EX 02 → EX
463-201-10B0 Rc1/4 42.5 <2.3> 42.5 <2.3> 53 <2.8> 53 <2.8> 30 or less Rc1/2 1.8
463-301-10B0 Rc3/8 56 <3.0> 56 <3.0> 67 <3.6> 80 <4.3>
463-401-10B0 Rc1/2 60 <3.2> 67 <3.6> 71 <3.8> 90 <4.8>
468-401-10B0 112 <6.0> 118 <6.3> 150 <8.1> 160 <8.6> 40 or less Rc1 3.5
468-601-10B0 Rc3/4 160 <8.6> 170 <9.1> 190 <10.2> 180 <9.7>
468-801-10B0 Rc1 180 <9.7> 190 <10.2> 190 <10.2> 200 <10.8>
468-A01-10B0 Rc1 1/4 180 <9.7> 190 <10.2> 190 <10.2> 200 <10.8> Rc1 1/4
46B-A00-11B0 400 <21.6> 450 <24.3> 425 <22.9> 530 <28.6> 50 or less Rc2 11.5
46B-B00-11B0 Rc1 1/2 480 <25.9> 500 <27.0> 500 <27.0> 560 <30.2>
46B-C00-11B0 Rc2 480 <25.9> 530 <28.6> 500 <27.0> 560 <30.2>

* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.

Notes:

  • Show the rated voltage at the end of the model No.
  • Model No. 46B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.

●Two-position double solenoid

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
Response time*
(msec)
EX port pipe connection threads Weight
(kg)
IN - OUT OUT - EX
IN → 01 IN → 02 01 → EX 02 → EX
463-201-20B0 Rc1/4 42.5 <2.3> 42.5 <2.3> 53 <2.8> 53 <2.8> 40 or less Rc1/2 1.9
463-301-20B0 Rc3/8 56 <3.0> 56 <3.0> 67 <3.6> 80 <4.3>
463-401-20B0 Rc1/2 60 <3.2> 67 <3.6> 71 <3.8> 90 <4.8>
468-401-20B0 112 <6.0> 118 <6.3> 150 <8.1> 160 <8.6> 40 or less Rc1 3.6
468-601-20B0 Rc3/4 160 <8.6> 170 <9.1> 190 <10.2> 180 <9.7>
468-801-20B0 Rc1 180 <9.7> 190 <10.2> 190 <10.2> 200 <10.8>
468-A01-20B0 Rc1 1/4 180 <9.7> 190 <10.2> 190 <10.2> 200 <10.8> Rc1 1/4
46B-A00-21B0 400 <21.6> 450 <24.3> 425 <22.9> 530 <28.6> 50 or less Rc2 12.1
46B-B00-21B0 Rc1 1/2 480 <25.9> 500 <27.0> 500 <27.0> 560 <30.2>
46B-C00-21B0 Rc2 480 <25.9> 530 <28.6> 500 <27.0> 560 <30.2>

* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.

Notes:

  • Show the rated voltage at the end of the model No.
  • Model No. 46B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.

●Three-position double solenoid closed center

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
Response time*
(msec)
EX port pipe connection threads Weight
(kg)
IN - OUT OUT - EX
IN → 01 IN → 02 01 → EX 02 → EX
463-201-30B0 Rc1/4 43 <2.3> 43 <2.3> 58 <3.1> 56 <3.0> 50 or less Rc1/2 2.9
463-301-30B0 Rc3/8 63 <3.4> 63 <3.4> 88 <4.7> 73 <3.9>
463-401-30B0 Rc1/2 76 <4.1> 76 <4.1> 100 <5.4> 80 <4.3>
468-401-30B0 124 <6.7> 124 <6.7> 175 <9.4> 150 <8.1> 60 or less Rc1 5.2
468-601-30B0 Rc3/4 175 <9.4> 175 <9.4> 250 <13.5> 180 <9.7>
468-801-30B0 Rc1 200 <10.8> 200 <10.8> 282 <15.2> 195 <10.5>
468-A01-30B0 Rc1 1/4 200 <10.8> 200 <10.8> 285 <15.4> 186 <10.0> Rc1 1/4
46B-A00-31B0 540 <29.2> 540 <29.2> 590 <31.9> 380 <20.5> 100 or less Rc2 15.3
46B-B00-31B0 Rc1 1/2 540 <29.2> 540 <29.2> 630 <34.0> 380 <20.5>
46B-C00-31B0 Rc2 545 <29.5> 545 <29.5> 680 <36.7> 390 <21.1>

* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.

Notes:

  • Show the rated voltage at the end of the model No.
  • Model No. 46B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.

●Three-position type double solenoid exhaust center

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
Response time*
(msec)
EX port pipe connection threads Weight
(kg)
IN - OUT OUT - EX
IN → 01 IN → 02 01 → EX 02 → EX
463-201-40B0 Rc1/4 37 <2.0> 37 <2.0> 41 <2.2> 40 <2.1> 30 or less Rc1/2 2.3
463-301-40B0 Rc3/8 58 <3.1> 58 <3.1> 78 <4.2> 65 <3.5>
463-401-40B0 Rc1/2 70 <3.7> 70 <3.7> 104 <5.6> 75 <4.0>
468-401-40B0 122 <6.5> 122 <6.5> 170 <9.1> 130 <7.0> 40 or less Rc1 4.1
468-601-40B0 Rc3/4 170 <9.1> 170 <9.1> 245 <13.2> 145 <7.8>
468-801-40B0 Rc1 195 <10.5> 195 <10.5> 280 <15.1> 150 <8.1>
468-A01-40B0 Rc1 1/4 196 <10.5> 196 <10.5> 280 <15.1> 150 <8.1> Rc1 1/4
46B-A00-41B0 450 <24.3> 450 <24.3> 540 <29.2> 265 <14.3> 40 or less Rc2 12.2
46B-B00-41B0 Rc1 1/2 510 <27.6> 510 <27.6> 645 <34.9> 270 <14.6>
46B-C00-41B0 Rc2 525 <28.4> 525 <28.4> 680 <36.7> 270 <14.6>

* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.

Notes:

  • Show the rated voltage at the end of the model No.
  • Model No. 46B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.

●Three-position double solenoid pressure center

Model No. Pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
Response time*
(msec)
EX port pipe connection threads Weight
(kg)
IN - OUT OUT - EX
IN → 01 IN → 02 01 → EX 02 → EX
463-201-50B0 Rc1/4 35 <1.8> 35 <1.8> 40 <2.1> 40 <2.1> 30 or less Rc1/2 2.3
463-301-50B0 Rc3/8 50 <2.7> 50 <2.7> 66 <3.5> 64 <3.4>
463-401-50B0 Rc1/2 53 <2.8> 53 <2.8> 73 <3.9> 70 <4.0>
468-401-50B0 120 <6.4> 120 <6.4> 153 <8.2> 145 <7.8> 40 or less Rc1 4.1
468-601-50B0 Rc3/4 175 <9.4> 175 <9.4> 185 <10.0> 170 <9.1>
468-801-50B0 Rc1 190 <10.2> 200 <10.8> 200 <10.8> 180 <9.7>
468-A01-50B0 Rc1 1/4 184 <9.9> 192 <10.3> 198 <10.7> 177 <9.5> Rc1 1/4
46B-A00-51B0 450 <24.3> 460 <24.9> 470 <25.4> 450 <24.3> 40 or less Rc2 12.2
46B-B00-51B0 Rc1 1/2 510 <27.6> 510 <27.6> 515 <27.8> 480 <25.9>
46B-C00-51B0 Rc2 510 <27.6> 510 <27.6> 540 <29.2> 500 <27.0>

* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.

Notes:

  • Show the rated voltage at the end of the model No.
  • Model No. 46B-_00 (Rc1 1/4 to Rc2) above uses the external pilot air supply method.

Model No.

46 3 - 2 01 - 1 0 B 0 AC100V
Product name [1] [2] [3] [4] [5] [6] [7]

[1]Basic body size

3 3/8B
8 1B
B 1 1/2B

[2]Pipe connection threads

2 Rc1/4
3 Rc3/8
4 Rc1/2
6 Rc3/4
8 Rc1
A Rc1 1/4
B Rc1 1/2
C Rc2

[3]Number of positions and function

1 Two-position type, single solenoid, normally open
2 Two-position type, double solenoid
3 Three-position type, closed center
4 Three-position type, exhaust center
5 Three-position type, pressure center

[4]Pilot air supply method

0 Internal pilot air supply method
1 External pilot air supply method

[5]Accessories

B Non-locking type manual push button and installation bracket
R Locking type manual push button and installation bracket

[6]Operation method

0 Solenoid
2 Solenoid with indicator lamp and surge killer

[7]Rated voltage

AC 100 V AC 100 V 50/60 Hz, AC 110 V 60 Hz
AC 200 V AC 200 V 50/60 Hz, AC 220 V 60 Hz
DC 24 V DC 24 V

Notes:

  • If a voltage other than the above is required, specify the voltage and cycle.
  • LUBRICATION UNITS FOR MACHINE TOOLS
  • PNEUMATIC EQUIPMENT FOR PRESS MACHINES
  • GENERAL PNEUMATIC EQUIPMENTS