PRODUCTSDIRECTION CONTROL VALVES (EXCEPT FOR DUAL VALVE)

Poppet Type Solenoid Valve for High/Low Pressure Switching (3-Port)

Model No. 363/8-_01, Model No. 36B-_00

Model No. 363/8-_01, Model No. 36B-_00
  • Poppet structure that facilitates maintenance
  • The external pilot method achieves reliable operation.
  • Ideal as a control valve for a large flow rate.
  • Valve with superior durability
  • Can be used without an oil supply.

Standard specifications

Operating fluid Compressed air purified by a filter
Operating pressure Pressure range on the main valve side*1 High pressure side (IN) 0.05-1.0 MPa
Low pressure side (EX) 0-0.85 MPa
Pilot pressure (P) setting*2 P = Pressure on the high pressure side (IN) + (0 to 0.2 MPa) and P ≥ Pressure on the low pressure side (EX) + (0.15 MPa)
Withstand pressure 1.6 MPa
Ambient temperature 5-50°C
Standard accessories Non-locking type manual push button and installation bracket
Rated voltage ・AC 100 V 50 Hz, AC 110 V 60 Hz
・AC 200 V 50 Hz, AC 220 V 60 Hz
・DC 24 V
Allowable voltage fluctuation rate −15% to +10% of the rated voltage
Insulation type Type B

*1. The high pressure side pressure (IN port) must be equal to or higher than the low pressure side pressure (EX port).
The operating pressure range of Model No. 36B-_00 (Rc1 1/4 to Rc2) is 0.2 to 1.0 MPa.

*2. Ensure that the pilot pressure does not exceed 1.0 MPa.

Current value of the solenoid (two-position type (external pilot method))

Two-position type
(external pilot method)
- Model No. 363/8-_01 Model No. 36B-_00
Voltage
/frequency
50 Hz 60 Hz 50 Hz 60 Hz
Striking current AC 100 V 0.30 A [0.065 A] 0.26 A [0.058 A] 0.510 A [0.750 A] 0.435 A [0.630 A]
AC 200 V 0.15 A [0.035 A] 0.13 A [0.032 A] 0.260 A [0.380 A] 0.220 A [0.335 A]
Holding current AC 100 V 0.20 A [0.040 A] 0.18 A [0.033 A] 0.240 A [0.240 A] 0.192 A [0.192 A]
AC 200 V 0.10 A [0.075 A] 0.09 A [0.019 A] 0.120 A [0.120 A] 0.096 A [0.096 A]
Direct current DC 24 V 0.40 A [0.075 A] 0.646 A [0.646 A]

Notes:

  • The current values in square brackets are for the two-position double solenoid model.

Typical characteristic values

●Two-position double solenoid

Model No. IN, OUT, and EX port pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
Response time*
(msec)
Weight (kg)
IN - OUT OUT - EX
363-201-91B0 Rc1/4 44 <2.4> 42 <2.3> 40 or less 1.4
363-301-91B0 Rc3/8 53 <2.8> 50 <2.7>
363-401-91B0 Rc1/2 55 <3.0> 60 <3.2>
368-401-91B0 125 <6.8> 135 <7.3> 40 or less 2.0
368-601-91B0 Rc3/4 180 <9.7> 170 <9.2>
368-801-91B0 Rc1 195 <10.5> 180 <9.7>
368-A01-91B0 Rc1 1/4 200 <10.8> 180 <9.7>
36B-A00-91B0 410 <22.2> 386 <20.9> 40 or less 7.0
36B-B00-91B0 Rc1 1/2 450 <24.4> 407 <22.0>
36B-C00-91B0 Rc2 480 <26.0> 423 <22.9>

* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.

Notes:

  • Show the rated voltage at the end of the model.

●Two-position single solenoid normally closed

Model No. IN, OUT, and EX port pipe connection threads Effective cross-sectional area (mm²)
< Cv value >
Response time*
(msec)
Weight (kg)
IN-OUT OUT-EX
363-201-81B0 Rc1/4 44 <2.4> 42 <2.3> 40 or less 1.1
363-301-81B0 Rc3/8 53 <2.8> 50 <2.7>
363-401-81B0 Rc1/2 55 <3.0> 60 <3.2>
368-401-81B0 125 <6.8> 135 <7.3> 40 or less 1.8
368-601-81B0 Rc3/4 180 <9.7> 170 <9.2>
368-801-81B0 Rc1 195 <10.5> 180 <9.7>
368-A01-81B0 Rc1 1/4 200 <10.8> 180 <9.7>
36B-A00-81B0 410 <22.2> 386 <20.9> 40 or less 6.4
36B-B00-81B0 Rc1 1/2 450 <24.4> 407 <22.0>
36B-C00-81B0 Rc2 480 <26.0> 423 <22.9>

* The response time is measured when the compressed air is 0.50 MPa.
The values in the table may be exceeded when the product starts after being left for a long time.

Notes:

  • Show the rated voltage at the end of the model.

Model No.

36 3 - 2 01 - 8 1 B 0 AC 100 V
Product name [1] [2] [3] [4] [5] [6]

[1]Basic body size

3 3/8B
8 1B
B 1 1/2B

[2]Pipe connection threads

2 Rc1/4
3 Rc3/8
4 Rc1/2
6 Rc3/4
8 Rc1
A Rc1 1/4
B Rc1 1/2
C Rc2

[3]Function

8 Single solenoid, dual supply
9 Double solenoid, dual supply

[4]Accessories

B Non-locking type manual push button and installation bracket
R Locking type manual push button and installation bracket

[5]Operation method

0 Solenoid
2 Solenoid with indicator lamp and surge killer

[6]Rated voltage

AC 100 V AC 100 V 50/60 Hz, AC 110 V 60 Hz
AC 200 V AC 200 V 50/60 Hz, AC 220 V 60 Hz
DC 24 V DC 24 V

Notes:

  • If a voltage other than the above is required, specify the voltage and cycle.
  • LUBRICATION UNITS FOR MACHINE TOOLS
  • PNEUMATIC EQUIPMENT FOR PRESS MACHINES
  • GENERAL PNEUMATIC EQUIPMENTS