PRODUCTSDIRECTION CONTROL VALVES (EXCEPT FOR DUAL VALVE)
Spool Operated Solenoid Valve (5-Port) (Sub-Base Type)
Model No. 524-_00
- No air loss
- Spool-integrated, low-sliding, soft sealing valve
- Supports concentrated exhaust.
- Sub-base type with DIN-connector connection
- Compact with large flow rate
Standard specifications
| Operating fluid | Compressed air filtered by a filter | |||
| Operating pressure range | 0.2-1.0 MPa | |||
| Withstand pressure | 1.5 MPa | |||
| Ambient temperature | 5-50°C | |||
| Lubrication | Lubrication required (turbine oil ISO VG32 or equivalent) | |||
| Operation frequency | At least once a month, 3 Hz or less | |||
| Manual operations | Non-locking type manual push button | |||
| Vibration/shock resistance | 3G/30G | |||
| Restriction on the installation direction | None | |||
| Ratings of the solenoid | Rated voltage | ・AC 100 V 50/60 Hz, AC 110 V 60 Hz ・AC 200 V 50/60 Hz, AC 220 V 60 Hz ・DC 24 V |
||
| Allowable voltage fluctuation rate | −10% to +10% of the rated voltage | |||
| Insulation type | Type B | |||
Current value of the solenoid
| - | Voltage/frequency | 50 Hz | 60 Hz |
| Striking current | AC 100 V | 0.065 A | 0.058 A |
| AC 200 V | 0.035 A | 0.032 A | |
| Holding current | AC 100 V | 0.040 A | 0.033 A |
| AC 200 V | 0.022 A | 0.019 A | |
| Direct current | DC 24 V | 0.085 A | |
Operating pressure and pilot pressure of the external pilot air supply method (optional)
| Flow operation method | Operating pressure on the main valve side | Pilot pressure for operation |
| Two-position type Single solenoid Model No. 524-_00-11_ _ |
0-0.2 MPa | ・When the pressure on the main valve side is 0 to 0.2 MPa: 0.2-0.3 MPa ・When the pressure on the main valve side is 0.2 MPa or more: Same pressure as on the main valve side |
| 0.2-1.0 MPa | ||
| Two-position type Double solenoid Model No. 524-_00-21_ _ |
0-0.15 MPa | |
| 0.15-1.0 MPa | ||
| Three-position type Model No. 524-_00-_1_ _ |
0-0.2 MPa | |
| 0.2-1.0 MPa |
Typical characteristic values
| Flow pattern | Pipe connection threads | Model No. (internal pilot air supply method, DIN) |
Effective cross-sectional area (mm²) |
Response time (msec) |
Weight (kg) |
|
| ON | OFF | |||||
| Two-position type Single solenoid |
Rc1/4 | 524-200-1003 | 42 | 45 | 65 | 1.8 |
| Rc3/8 | 524-300-1003 | 68 | ||||
| Rc1/2 | 524-400-1003 | 80 | ||||
| Rc3/4 | 524-600-1003 | 80 | 1.9 | |||
| Two-position type Double solenoid |
Rc1/4 | 524-200-2003 | 42 | 26 | 2 | |
| Rc3/8 | 524-300-2003 | 68 | ||||
| Rc1/2 | 524-400-2003 | 80 | ||||
| Rc3/4 | 524-600-2003 | 80 | 2.1 | |||
| Three-position type Closed center |
Rc1/4 | 524-200-3003 | 41 | 20 | 70 | 2.1 |
| Rc3/8 | 524-300-3003 | 60 | ||||
| Rc1/2 | 524-400-3003 | 75 | ||||
| Rc3/4 | 524-600-3003 | 75 | 2.2 | |||
| Three-position type Exhaust center |
Rc1/4 | 524-200-4003 | 41 | 20 | 70 | 2.1 |
| Rc3/8 | 524-300-4003 | 60 | ||||
| Rc1/2 | 524-400-4003 | 75 | ||||
| Rc3/4 | 524-600-4003 | 75 | 2.2 | |||
| Three-position type Pressure center |
Rc1/4 | 524-200-5003 | 41 | 20 | 70 | 2.1 |
| Rc3/8 | 524-300-5003 | 60 | ||||
| Rc1/2 | 524-400-5003 | 75 | ||||
| Rc3/4 | 524-600-5003 | 75 | 2.2 | |||
Model No.
| 524 | - | 0 | 0 | 0 | - | 1 | 0 | 0 | 0 | DC 24 V |
| Product name | [1] | [2] | [3] | [4] | [5] | [6] | [7] |
[1]Pipe connection threads
| 0 | Without sub base |
| 2 | Rc1/4 |
| 3 | Rc3/8 |
| 4 | Rc1/2 |
| 6 | Rc3/4 |
[2]Thread standard
| 0 | Rc threads |
| G | G threads |
| N | NPT threads |
[3]Number of positions and function
| 1 | Two-position type, single solenoid |
| 2 | Two-position type, double solenoid |
| 3 | Three-position type, closed center |
| 4 | Three-position type, exhaust center |
| 5 | Three-position type, pressure center |
[4]Pilot air supply method
| 0 | Internal pilot air supply method |
| 1 | External pilot air supply method |
[5]Accessories
| 0 | Non-locking type push button |
| 1 | Locking type push button |
[6]Electrical wiring
| 0 | DIN-Pg 11 connector |
| 2 | DIN-Pg 11 connector with indicator lamp and surge killer |
| 3 | DIN-Pg 9 connector |
| 4 | DIN-Pg 9 connector with indicator lamp and surge killer |
[7]Rated voltage
| AC 100 V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.
Main precautions for use
[Basic]
Make sure to use the product within the specifications.
When using the product in a low-temperature environment, treat water in the fluid using an air dryer or other device to prevent gelation.
Prevent interference accidents in operating equipment during an abrupt power shutdown or the subsequent restoration.
- Use the product at the appropriate voltage and frequency.
- Use the product at or below the maximum operating pressure.
- Use the specified fluid (clean compressed air).
- Do not use the product in a location where there is a risk of fire or explosion.
When using the product in a low-temperature environment, treat water in the fluid using an air dryer or other device to prevent gelation.
Prevent interference accidents in operating equipment during an abrupt power shutdown or the subsequent restoration.
[Piping and installation]
Remove the port protection plug (or sealing) immediately before piping.
Use sufficiently flushed pipes.
Do not let seal materials enter the pipe during piping.
Properly install pipes, checking the display at each port.
Ensure space for maintenance around equipment.
Do not make the exhaust port smaller.
Install the silencer so that it will not come off.
Use sufficiently flushed pipes.
Do not let seal materials enter the pipe during piping.
Properly install pipes, checking the display at each port.
Ensure space for maintenance around equipment.
Do not make the exhaust port smaller.
Install the silencer so that it will not come off.
[Electrical wiring]
Check the power supply voltage to confirm safety before wiring.
For a double solenoid model, prevent both solenoids from becoming live at the same time.
For a double solenoid model, prevent both solenoids from becoming live at the same time.
[Operation]
Confirm in advance that operating the manual button will not cause an accident due to the operation of equipment on the OUT side.
Make sure to return the locking type manual button to its original position after operating it.
Make sure to return the locking type manual button to its original position after operating it.
[Maintenance]
Conduct daily and periodic inspections according to a plan.
Make sure to turn off the power and decrease the air pressure to 0 (zero) in equipment, and before and after it, before repair and overhaul.
Make sure to turn off the power and decrease the air pressure to 0 (zero) in equipment, and before and after it, before repair and overhaul.
Model No. MVS/D-491, Model No. MVD-4_1 (Three-position type)
- Sub-base type (Rc1 1/4 to Rc1 1/2)
- Soft sealing spool valve
- Large effective cross-sectional area
- Various sizes to operate Ø32 to Ø320 cylinders
- Rated voltage: AC 100/200 V (50/60 Hz), DC 24 V
Standard specifications
| Operating fluid | Compressed air filtered by a filter | |||||
| Operating pressure range | 0.15-1.0 MPa | |||||
| Ambient temperature | 5-50°C | |||||
| Lubrication | Oil supply required (ISO VG32 turbine oil or equivalent) | |||||
| Operation frequency | At least once a month, 3 Hz or less | |||||
| Manual operations | Non-locking type manual push button | |||||
| Ratings of the solenoid | Rated voltage | ・AC 100 V 50/60 Hz, AC 110 V 60 Hz ・AC 200 V 50/60 Hz, AC 220 V 60 Hz ・DC 24 V |
||||
| Allowable voltage fluctuation rate | −15% to +10% of the rated voltage | |||||
| Insulation type | Type B | |||||
Current value of the solenoid
| - | Voltage/frequency | 50 Hz | 60 Hz |
| Striking current | AC 100 V | 0.210 A | 0.435 A |
| AC 200 V | 0.260 A | 0.220 A | |
| Holding current | AC 100 V | 0.240 A | 0.192 A |
| AC 200 V | 0.120 A | 0.096 A | |
| Direct current | DC 24 V | 0.646 A (15.5 W) | |
Typical characteristic values
| Operation category | Pipe connection threads | Model No. | Effective cross-sectional area (mm²) |
Response time (msec) |
Weight (kg) |
|
| ON | OFF | |||||
| Two-position type Single solenoid |
Rc1 1/4 | MVS-491-12Y | 330 | 60 | 130 | 10.5 |
| Rc1 1/2 | MVS-491-14Y | 350 | ||||
| Two-position type Double solenoid |
Rc1 1/4 | MVD-491-12Y | 330 | 32 | - | 11.4 |
| Rc1 1/2 | MVD-491-14Y | 350 | ||||
| Three-position type Closed center |
Rc1 1/4 | MVD-431-12Y | 330 | 35 | 70 | 12.4 |
| Rc1 1/2 | MVD-431-14Y | 350 | ||||
| Three-position type Exhaust center |
Rc1 1/4 | MVD-441-12Y | 330 | |||
| Rc1 1/2 | MVD-441-14Y | 350 | ||||
| Three-position type Pressure center |
Rc1 1/4 | MVD-451-12Y | 330 | |||
| Rc1 1/2 | MVD-451-14Y | 350 | ||||
Model No.
| MV | S | - | 491 | - | 12Y | H | A | P | R | DC 24 V |
| [1] | [2] | [3] | [4] | [5] | [6] | [7] | [8] |
[1]Number of solenoids
| S | Single solenoid |
| D | Double solenoid |
[2]Number of positions and function
| 431 | Three-position type, closed center |
| 441 | Three-position type, exhaust center |
| 451 | Three-position type, pressure center |
| 491 | Two-position type, single solenoid, double solenoid |
[3]Pipe connection threads
| 12Y | Rc1 1/4 |
| 14Y | Rc1 1/2 |
[4]Voltage type
| Blank | AC |
| H | DC |
[5]Use
| Blank | Standard |
| A | Dual supply |
[6]Pilot air supply method
| Blank | Internal pilot air supply method |
| P | External pilot air supply method |
[7]Accessories
| Blank | Non-locking type manual button |
| R | Locking type manual button (screw-on) |
| S | Indicator lamp and surge killer |
[8]Rated voltage
| AC 100 V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.
Model No. MVS/D-492, Model No. MVD-4_2 (Three-position type)
- Sub-base type (Rc3/4 to Rc1 1/4)
- Soft sealing spool valve
- Large effective cross-sectional area
- Various sizes to operate Ø32 to Ø320 cylinders
- Rated voltage: AC 100/200 V (50/60 Hz), DC 24 V
Standard specifications
| Operating fluid | Compressed air filtered by a filter | |||||
| Operating pressure range | 0.15-1.0 MPa | |||||
| Ambient temperature | 5-50°C | |||||
| Lubrication | Oil supply required (turbine oil ISO VG32 or equivalent)* | |||||
| Operation frequency | At least once a month, 3 Hz or less | |||||
| Manual operations | Non-locking type manual push button | |||||
| Ratings of the solenoid | Rated voltage | ・AC 100 V 50/60 Hz, AC 110 V 60 Hz ・AC 200 V 50/60 Hz, AC 220 V 60 Hz ・DC 24 V |
||||
| Allowable voltage fluctuation rate | −15% to +10% of the rated voltage | |||||
| Insulation type | Type B | |||||
* Can be used even without an oil supply.
Current value of the solenoid
| - | Voltage/frequency | 50 Hz | 60 Hz |
| Striking current | AC 100 V | 0.165 A | 0.140 A |
| AC 200 V | 0.080 A | 0.068 A | |
| Holding current | AC 100 V | 0.102 A | 0.079 A |
| AC 200 V | 0.049 A | 0.039 A | |
| Direct current | DC 24 V | 0.270 A | |
Typical characteristic values
| Operation category | Pipe connection threads | Model No. | Effective cross-sectional area (mm²) |
Response time (msec) |
Weight (kg) |
|
| ON | OFF | |||||
| Two-position type Single solenoid |
Rc3/4 | MVS-492-06Y | 185 | 59 | 134 | 3.6 |
| Rc1 | MVS-492-10Y | 195 | ||||
| Rc1 1/4 | MVS-492-12JY | 215 | 4.6 | |||
| Two-position type Double solenoid |
Rc3/4 | MVD-492-06Y | 185 | 69 | - | 4.5 |
| Rc1 | MVD-492-10Y | 195 | ||||
| Rc1 1/4 | MVD-492-12JY | 215 | 5.3 | |||
| Three-position type Closed center |
Rc3/4 | MVD-432-06Y | 185 | 166 | 76 | 5.3 |
| Rc1 | MVD-432-10Y | 195 | ||||
| Rc1 1/4 | MVD-432-12JY | 215 | 6.1 | |||
| Three-position type Exhaust center |
Rc3/4 | MVD-442-06Y | 185 | 166 | 76 | 5.3 |
| Rc1 | MVD-442-10Y | 195 | ||||
| Rc1 1/4 | MVD-442-12JY | 215 | 6.1 | |||
| Three-position type Pressure center |
Rc3/4 | MVD-452-06Y | 185 | 166 | 76 | 5.3 |
| Rc1 | MVD-452-10Y | 195 | ||||
| Rc1 1/4 | MVD-452-12JY | 215 | 6.1 | |||
Model No.
| MV | S | - | 492 | - | 06Y | H | A | P | R | DC 24 V |
| [1] | [2] | [3] | [4] | [5] | [6] | [7] | [8] |
[1]Number of solenoids
| S | Single solenoid |
| D | Double solenoid |
[2]Number of positions and function
| 432 | Three-position type, closed center |
| 442 | Three-position type, exhaust center |
| 452 | Three-position type, pressure center |
| 492 | Two-position type, single solenoid, double solenoid |
[3]Pipe connection threads
| 06Y | Rc3/4 |
| 10Y | Rc1 |
| 12JY | Rc1 1/4 (overport) |
[4]Voltage type
| Blank | AC |
| H | DC |
[5]Use
| Blank | Standard |
| A | Dual supply |
[6]Pilot air supply method
| Blank | Internal pilot air supply method |
| P | External pilot air supply method |
[7]Accessories
| Blank | Non-locking type manual button |
| R | Locking type manual button (screw-on) |
| S | Indicator lamp and surge killer |
[8]Rated voltage
| AC 100 V | AC 100 V 50/60 Hz, AC 110 V 60 Hz |
| AC 200 V | AC 200 V 50/60 Hz, AC 220 V 60 Hz |
| DC 24 V | DC 24 V |
Notes:
- If a voltage other than the above is required, specify the voltage and cycle.