PRODUCTSPRESSURE SWITCH
Air Purge Valve for Gap-Sensing Pressure Switch
Model No. MVS-214-02
- Constantly blows out micro pressure air from the detection nozzle to purge cutting fluid and debris.
The amount of purge air can be adjusted. - Turn ON the solenoid to switch it to supply the necessary amount of air for detection at the detection phase.
- Does not waste air (saves energy) and significantly improves the reliability of the detection system.
(In a calculation example, air consumption was reduced to one-fourth.) - An indicator lamp and surge voltage protection circuit are included as standard.
- Can be turned ON/OFF using the manual operation lever.
Standard specifications
| Operating fluid | Compressed air that has gone through a 5-μm filter (oil-less) | |||||
| Operating pressure | 0.2 MPa max. | |||||
| Ambient temperature | 5-50°C | |||||
| Effective cross-sectional area | 5 mm² | |||||
| Purge flow rate adjustment range | 0.6-1.6 dm³/min (ANR) | |||||
| Manual operations | Lever system (two positions) | |||||
| Weight | 0.45 kg | |||||
| Solenoid model | Rated voltage | ・AC 100 V 50/60 Hz, AC 110 V 60 Hz ・AC 200 V 50/60 Hz, AC 220 V 60 Hz ・DC 24 V |
||||
| Electrical connection connector | ・DIN-type Pg11 ・With indicator lamp and surge protection circuit |
|||||
| Allowable voltage fluctuation rate | −15% to +10% | |||||
| Insulation type | Type B | |||||
Current value of the solenoid
| - | Voltage/frequency | 50 Hz | 60 Hz |
| Striking current | AC 100 V | 0.165 A | 0.140 A |
| AC 200 V | 0.080 A | 0.068 A | |
| Holding current | AC 100 V | 0.102 A | 0.079 A |
| AC 200 V | 0.049 A | 0.039 A | |
| Direct current | DC 24 V | 0.27 A | |