PRODUCTSPRESSURE SWITCH

High-Precision Mechanical Pressure Switch

Model No. PSD-101

Model No. PSD-101
  • Allows you to set the pressure just by aligning the scale.
  • Small open/close pressure difference (≈ 0.01 MPa max.)
  • The pressure can be precisely set with high repeat accuracy (±0.003 MPa).
  • Robust for long-term safe use
  • Models with an indicator lamp that lights up when switching occurs are also available.
  • The installation bracket is included.

Standard specifications

Operating fluid Compressed air or non-corrosive gas
Allowable pressure 1.0 MPa
Pressure error from the dial scale ±3% FS max. (at 23°C)
Switch contact model 1c 1c
Pipe connection threads Rc1/4
Maximum operating pressure 1.0 MPa
Operating temperature −10-50°C
Weight 1.5 kg

Model No.

PSD - 101 A K1 ST 1 T
Product name [1] [2] [3] [4] [5]

[1]Contact type

Blank High-sensitivity contact model (standard)
Contact capacity (resistance load)
15 A: AC 125/250 V
2 A: DC 24 V
A Minimal load contact model
Contact capacity (resistance load)
Up to 0.1 A: AC 100 V
Up to 0.1 A: DC 24 V

[2]Set pressure (MPa)

Blank 0.30-0.90
K1 0.01-0.10
K5 0.05-0.50

[3]Inclusion of indicator lamp and its color

Blank No indicator lamps. COM and NO are connected if the pressure rises.
ST With indicator lamp (transparent)
SG With indicator lamp (green)
SR With indicator lamp (red)

[4]Characteristics

Blank No indicator lamps. COM and NO are connected if the pressure rises.
1 AC 100 V. The lamp turns off and the load is applied if the pressure rises.
2 AC 200 V. The lamp turns off and the load is applied if the pressure rises.
Notes: Cannot be set in the minimal load contact model (PSD-101A).
3 DC 24 V. The lamp turns on and the load is applied if the pressure rises.
3P DC 24 V. The lamp turns on and the load is applied if the pressure drops.

[5]Pressure gauge

Blank Without pressure gauge
T With pressure gauge
Indicator lamp Model No. Indicator lamp circuit
High-sensitivity contact model Minimal load contact model
Standard
(without indicator lamp)
PSD-101
PSD-101K1
PSD-101K5
PSD-101A
PSD-101AK1
PSD-101AK5
COM and NO are connected if the pressure rises. Switch terminal only
AC 100 V
Indicator lamp (neon)
PSD-101ST1
PSD-101K1ST1
PSD-101K5ST1
PSD-101AST1
PSD-101AK1ST1
PSD-101AK5ST1

The lamp turns off and the load is applied if the pressure rises.
When the connection terminal for the indicator lamp is changed to the NC side, the indicator lamp lights up if the pressure rises.

AC 200 V
Indicator lamp (neon)
PSD-101ST2
PSD-101K1ST2
PSD-101K5ST2
-
DC 24 V
Indicator lamp (LED)
PSD-101ST3
PSD-101K1ST3
PSD-101K5ST3
PSD-101AST3
PSD-101AK1ST3
PSD-101AK5ST3
The lamp turns on and the load is applied if the pressure rises.
PSD-101ST3P
PSD-101K1ST3P
PSD-101K5ST3P
PSD-101AST3P
PSD-101AK1ST3P
PSD-101AK5ST3P
The lamp turns on and the load is applied if the pressure drops.
  • LUBRICATION UNITS FOR MACHINE TOOLS
  • PNEUMATIC EQUIPMENT FOR PRESS MACHINES
  • GENERAL PNEUMATIC EQUIPMENTS